The theoretical nominal torque applies only for ideal concentricity between the inner and outer ring.
The maximum transmissible torque is 2 times the specified nominal torque. See page 14 for determination of selection torque.
WHAT ARE YOU LOOKING FOR?
*
This field is required
Total quantity you need
*
This field is required
*
This field is required
Email format error
Due to email instability, you might miss our correspondence. Please provide your phone number for alternative contact.
This field is required
Telephone information is wrong!
Send Message
//www.suma-china.com/uploadfiles/107.151.154.110/webid106/source/201601/145325542059.png
Product Detail

Features
Cage Freewheels SF are sprag freewheels to be
installed between customer-supplied inner and
outer rings.
The freewheels SF are used as:
➧ Backstops
➧ Overrunning Clutches
➧ Indexing Freewheels
In addition to the standard type, two other
types are available for extended service life.
Nominal torques up to 93 000 Nm.

Mounting
The lateral guidance of the Cage Freewheels
can be effected either by a shoulder on the
outer ring or by guard rings or guard discs
which are fixed in the outer ring.
Torque transmission capacity can be increased
if several cages are arranged side by side. In this
case please consult with RINGSPANN on trans-
missible torques.
Please note the technical points on page 118
regarding the sprag tracks.

Example for ordering
Freewheel size SF 44-14,5, standard type:
• SF 44-14,5 K


Sizes of Cage Freewheels SF

Different types of Cage Freewheels SF

Freewheel Size

Type

Nominal t orque
MN
Nm

Type

Nominal t orque
MN
Nm

Type

Nominal t orque
MN
Nm

Sprag lift-off at outer ring speed min-1

J
mm

D
mm

B
mm

K
mm

Sprags Quantity

Weight
kg

SF18-13,5

J

66

18,80

35,47

13,5

50

10

0,04

SF23-13,5

J

120

23,63

40,29

13,5

55

12

0,04

SF27-13,5

J

160

JT

160

JZ

100

3 600

27,78

44,42

13,5

65

14

0,05

SF31-13,5

J

170

JT

170

JZ

110

3 400

31,75

48,41

13,5

70

12

0,04

SF32-21,5

J

400

32,77

49,44

21,5

65

14

0,07

SF37-14,5

K

270

KT

270

KZ

210

2 900

37

55

14,5

75

14

0,06

SF42-21

J

720

42,10

58,76

21

85

18

0,09

SF44-14,5

K

500

KT

500

KZ

400

2 250

44

62

14,5

90

20

0,08

SF46-21

J

840

46,77

63,43

21

90

20

0,10

SF50-18,5

K

680

KT

680

KZ

580

2 250

50

68

18,5

90

20

0,10

SF56-21

J

1 050

56,12

72,78

21

100

22

0,11

SF57-18,5

K

950

KT

950

KZ

800

2 000

57

75

18,5

105

24

0,13

SF61-21

J

1 300

JT

1 300

JZ

1 150

1 550

61,91

78,57

21

110

26

0,14

SF72-23,5

K

2 100

KT

2 100

KZ

1 850

1 550

72

90

23,5

135

32

0,23

SF82-25

K

2 300

KT

2 300

KZ

2 100

1 450

82

100

25

140

36

0,26

SF107-25

K

3 300

KT

3 300

KZ

3 100

1 300

107

125

25

170

48

0,35

SF127-25

K

4 900

KT

4 900

KZ

4 600

1 200

127

145

25

210

56

0,40

SF140-50

S

13 600

ST

13 600

SZ

10 500

950

140

180

50

260

24

1,70

SF140-63

S

18 000

ST

18 000

SZ

14 000

800

140

180

63

260

24

2,00

SF170-50

S

17 000

ST

17 000

SZ

13 500

880

170

210

50

290

28

1,95

SF170-63

S

23 000

ST

23 000

SZ

18 500

720

170

210

63

290

28

2,40

SF200-50

S

23 000

ST

23 000

SZ

18 500

820

200

240

50

325

36

2,50

SF200-63

S

29 000

ST

29 000

SZ

23 500

680

200

240

63

325

36

3,10

SF230-63

S

37 000

ST

37 000

SZ

29 500

650

230

270

63

360

45

3,90

SF270-50

S

35 000

ST

35 000

SZ

29 500

720

270

310

50

410

48

3,40

SF270-63

S

44 000

ST

44 000

SZ

37 000

600

270

310

63

410

48

4,20

SF340-50

S

45 000

ST

45 000

SZ

43 000

640

340

380

50

510

60

4,20

SF340-63

S

67 500

ST

67 500

SZ

57 500

540

340

380

63

510

60

5,20

SF380-50

S

57 000

ST

57 000

SZ

48 500

610

380

420

50

550

63

4,40

SF440-63

S

93 000

ST

93 000

SZ

80 000

470

440

480

63

640

72

6,20

The theoretical nominal torque applies only for ideal concentricity between the inner and outer ring.

The maximum transmissible torque is 2 times the specified nominal torque. See page 14 for determination of selection torque.

Related products
Related news
Inquire Now
Name: *
Mobile:
E-mail: *
Message: *
Verification code: *
  
Related products
Other products
Hot products
BE THE FIRST TO KNOW !
Please write down your information to facilitate inquiries about our related products
    bottom_logo

    On the other hand denoune with righteou indignat and dislike menar so beguiled demoralized echarms of pleasure of the moment so blinded by desire that systems.

      Contact Us

      E-mail: ellen@chinasuma.com

      Mobile: 0086-18068536660

      Tel: 0086-519-85858018

      Fax: 0086-519 85858018

      WhatsApp: +86-18068536660

      Add: Liudao Industrial Park, YaoguanTown, Wujin District , Changzhou City , Jiangsu Province, China , 213102

    CopyRight © 2024 Changzhou Suma Precision Machinery Co., Ltd All rights reserved Sitemap  All tags